Real Time Automation
Member: Yes
Address:
N26 W23315 Paul Road
Pewaukee, WI 53072 USA
Phone: +1 262-436-9299
Fax:
Web Site: www.rtautomation.com
Contact: John Rinaldi
Email: solutions@rtautomation.com
Description:
Real Time Automation delivers easy to use, simple to maintain networking solutions. Whether you need an off the shelf gateway to move data between different networks, a daughter card to network enable a serial device, or source code to add to your embedded processors - Real Time Automation is here to help. Our simple solutions and industry leading support are guaranteed to save you time, money and headaches. You get support from an engineer who developed the product and a product made in the USA that is always stocked. With RTA you can take a solution from discovered to implemented in a day. RTA's team of leading automation engineers has a proven track record of delivering on time, on budget, and to conformance standards, with its vast working knowledge of Modbus TCP, Modbus RTU, DeviceNet, EtherNet/IP, LonWorks, PROFINET IO, Profibus, AS Interface, CANopen, and BACnet.See list of news items about this company...
Product Name | Type | Connectivity | Product Description |
---|---|---|---|
Modbus TCP Client to BACnet MS/TP Server, 460 MSBM | Network Gateway | Modbus TCP | The 460MSBM moves data between a network of up to 32 BACnet MS/TP Server devices and a Modbus TCP Client. It's a perfect tool to get your Modbus TCP data tied in with your BACnet MS/TP devices. |
TCP Client to BACnet MS/TP Client, 460 MSBMS | Network Gateway | Modbus TCP | The 460MSBMS moves data between a Modbus TCP Client and a BACnet MS/TP Building Automation System (BAS). It's a perfect tool to get your Modbus TCP data tied in with your BACnet MS/TP Building Automation System. |
Modbus TCP Client to BACnet/IP Servers, 460 MSBC | Network Gateway | Modbus TCP | The 460MSBC moves data between a network of up to 32 BACnet/IP Server devices and a Modbus TCP Client. It's a perfect tool to get your Modbus TCP data tied in with your BACnet/IP devices. |
Modbus TCP Client to Modbus RTU Client, 460 MSMRS | Network Gateway | Modbus TCP | The 460MSMRS moves data between a Modbus TCP Client device and a Modbus RTU Client device. Data can be freely moved between your Modbus RTU and Modbus TCP controllers. |
Modbus TCP Server to Ethernet TCP/IP, 460 MCTCP | Network Gateway | Modbus TCP | The 460MCTCP moves data between up to 32 Modbus TCP Servers and an Ethernet TCP/IP device. With the 460MCTCP you have a tool to help you map Modbus TCP device data into an Ethernet TCP/IP application. You can also capture Ethernet TCP/IP commands and write them to your Modbus TCP Server devices. |
Modbus TCP Server to DeviceNet Servers, 460 MCDM | Network Gateway | Modbus TCP | The 460MCDM moves data between a network of up to 32 Modbus TCP Server devices and up to 32 DeviceNet Servers. It's the perfect tool to tie all of your Modbus TCP devices into your DeviceNet network. |
Modbus TCP Server to Profibus DP Controller, 460 MCPBS | Network Gateway | Modbus TCP | The 460MCPBS moves data between up to 32 Modbus TCP Server devices and a Profibus DP enabled PLC. It's the perfect tool to utilize the plethora of cost-effective Modbus TCP devices in your Profibus architecture. |
Modbus TCP Server to Modbus RTU Server, 460 MCMM | Network Gateway | Modbus TCP | The 460MCMM moves data between up to 32 Modbus TCP Server devices and up to 32 Modbus RTU Server devices. With the 460MCMM register and coil data can be freely moved between your Modbus RTU and Modbus TCP networks. |
Modbus TCP to BACnet/IP Server, 460 MCBC | Network Gateway | Modbus TCP | The 460MCBC moves data between up to 32 Modbus TCP Servers and up to 32 BACnet/IP Servers. It's a perfect tool to move data between your Modbus power meters, boilers, chiller and other Server devices and your BACnet/P Server devices. |
Modbus RTU Client to BACnet MS/TP Servers, 460 MRSBM | Network Gateway | Modbus RTU | The 460MRSBM moves data between a Modbus RTU Client device and up to 32 BACnet MS/TP Server devices. With the 460MRSBM you're mapping BACnet MS/TP as Binary and Analog values directly to your Modbus RTU Client. |
Modbus RTU Client to BACnet MS/TP Client, 460 MRSBMS | Network Gateway | Modbus RTU | The 460MRSBMS moves data between a Modbus RTU Client and a BACnet MS/TP Building Automation System (BAS). It's a perfect tool to get your Modbus RTU data tied in with your BACnet MS/TP Building Automation System. |
Modbus TCP Client to Profinet IO Controller Gateway, 460PSMS | Network Gateway | Modbus TCP | The 460PSMS moves data between a Modbus TCP/IP Client device and a Profinet IO Controller. With the 460PSMS you are making a direct connection between Modbus TCP/IP Client Register and Coil data and user defined Slots in your Profinet IO Controller. The 460PSMS provides an option to access a Modbus TCP/IP Client device without having to upgrade your PLC or get an expensive in rack solution. |
Modbus TCP Server to Profinet IO Controller Gateway, 460PSMC | Network Gateway | Modbus TCP | The 460PSMC moves data between up to 32 Modbus TCP/IP Server devices and a Profinet IO Controller. With the 460PSMC you are making a direct connection between Modbus TCP/IP Server data and user defined Slots in your Profinet IO Controller. The 460PSMC provides an option to access Modbus TCP/IP Server devices without having to upgrade your PLC or get an expensive in rack solution. |
Modbus RTU Client to Profinet IO Controller Gateway, 460PSMRS | Network Gateway | Modbus RTU | The 460PSMRS moves data between a Modbus RTU Client device and a Profinet IO Controller. With the 460PSMRS you are making a direct connection between Modbus RTU Client Register and Coil data and user defined Slots in your Profinet IO Controller. The 460PSMRS provides an option to access your Modbus RTU Client device without having to upgrade your PLC or get an expensive in rack solution. |
Modbus RTU Server to Profibus DP Client Gateway, 460MMPBS | Network Gateway | Modbus RTU | The 460MMPBS moves data between up to 32 Modbus RTU Server devices and a Profibus DP enabled PLC. With the 460MMPBS you are making a direct connection between Modbus RTU Server data and user defined Slots in your Profibus DP PLC. The 460MMPBS provides an option to access Modbus RTU Server devices without having to upgrade your PLC or get an expensive in rack solution. |
Modbus RTU Server to Profinet IO Controller Gateway, 460PSMM | Network Gateway | Modbus RTU | The 460PSMM moves data between up to 32 Modbus RTU Server devices and a Profinet IO Controller. With the 460PSMM you make a direct connection between Modbus RTU Server data and user defined Slots in your Profinet IO Controller. The 460PSMM provides an option to access Modbus RTU Server devices without having to upgrade your PLC or get an expensive in rack solution. |
Modbus TCP Client to EtherNet/IP Scanner Gateway, 460ESMS | Network Gateway | Modbus TCP | The 460ESMS moves data between a Modbus TCP Client and an EtherNet/IP Scanner. Directly map Modbus TCP Register and Coil data to an EtherNet/IP Scanner |
Modbus TCP/IP Client to Allen-Bradley PLC Gateway, 460ETCMS | Network Gateway | Modbus TCP | The 460ETCMS moves data between a Modbus TCP Client and an Allen-Bradley PLC. Directly maps Modbus TCP data and user defined Tags or Registers in the data table of your Allen-Bradley PLC |
Modbus TCP/IP Client to DeviceNet Client Gateway, 460MSDS | Network Gateway | Modbus TCP | The 460MSDS moves data between a Modbus TCP Client and a DeviceNet Client. Directly maps Modbus TCP register and coil data to a DeviceNet Client. |
Modbus TCP/IP Client to Ethernet TCP/IP Gateway, 460MSTCP | Network Gateway | Modbus TCP | The 460MSTCP moves data between up to 10 Ethernet TCP/IP devices and a Modbus TCP Client. Directly maps Ethernet TCP/IP data to registers and coils in a Modbus TCP Client |
Modbus TCP/IP Client to EtherNet/IP Adapter Gateway, 460ECMS | Network Gateway | Modbus TCP | The 460ECMS moves data between up to 32 EtherNet/IP and a Modbus TCP Client. Modbus is still the catch all protocol. It's simple and been around forever, which means there is huge base of users and legacy systems supporting Modbus. With the 460ECMS you now have a great tool to integrate newer EtherNet/IP devices into these systems. |
Modbus TCP/IP Client to BACnet/IP Client Gateway, 460MSBS | Network Gateway | Modbus TCP | The 460MSBS moves data between a Modbus TCP Client and a BACnet/IP Client. Directly map Modbus RTU Register and Coil data to a BACnet/IP Client |
DeviceNet Server to Modbus TCP/IP Client Gateway, 460MSDM | Network Gateway | Modbus TCP | The 460MSDM moves data between up to 32 DeviceNet Server devices and a Modbus TCP Client. Directly map DeviceNet data to Registers and Coils in a Modbus TCP Client |
Modbus TCP/IP Client to ASCII Gateway, 460MSA | Network Gateway | Modbus TCP | The 460MSA moves data between a Modbus TCP/IP Client and an ASCII device. Directly map ASCII data to a Modbus TCP Client |
Modbus TCP/IP Server to BACnet MS/TP Client Gateway, 460MCBMS | Network Gateway | Modbus TCP | The 460MCBMS moves data between up to 32 Modbus TCP Server devices and a BACnet MS/TP Client. Directly map Modbus TCP Register and Coil data to BACnet MS/TP network |
Modbus TCP/IP Server to DeviceNet Client Gateway, 460MCDS | Network Gateway | Modbus TCP | The 460MCDS moves data between up to 32 Modbus TCP Server devices and a DeviceNet Client. Directly map Modbus TCP Register and Coil data to a DeviceNet network. |
Modbus TCP/IP Server to Allen-Bradley PLC Gateway, 460ETCMC | Network Gateway | Modbus TCP | The 460ETCMC moves data between up to 31 Modbus TCP Server devices and an Allen-Bradley PLC. Directly map Modbus TCP data and user-defined Tags or Registers in the data table of an Allen-Bradley PLC. |
Modbus TCP/IP Server to ASCII Gateway, 460MCA | Remote Terminal Unit | Modbus TCP | The 460MCA moves data between up to 32 Modbus RTU Server devices and an ASCII device. Directly map Modbus TCP Register and Coil data to an ASCII device. |
Modbus TCP/IP Server to EtherNet/IP Scanner, 460ESMC | Network Gateway | Modbus TCP | The 460ESMC moves data between up to 32 Modbus TCP Servers and an EtherNet/IP Scanner. Directly map Modbus TCP Register and Coil data to an EtherNet/IP Scanner. |
Modbus TCP/IP Server to BACnet/IP Client Gateway, 460MCBS | Network Gateway | Modbus TCP | The 460MCBS moves data between up to 32 Modbus TCP Server devices and a BACnet/IP Client. Directly map Modbus TCP Register and Coil data to a BACnet/IP Client. |
Modbus RTU Client to Allen-Bradley PLC Gateway, 460ETCMRS | Network Gateway | Modbus RTU | The 460ETCMRS moves data between a Modbus RTU Client and an Allen-Bradley PLC. Directly map Modbus RTU data and user-defined Tags or Registers in the data table of your Allen-Bradley PLC. |
Modbus RTU Client to Ethernet TCP/IP Gateway, 460MRSTCP | Network Gateway | Modbus RTU | The 460MRSTCP moves data between up to 10 Ethernet TCP/IP devices and a Modbus RTU Client. Directly map Ethernet TCP/IP data to Registers and Coils in a Modbus RTU Master. |
Modbus RTU Client to DeviceNet Client Gateway, 460MRSDS | Network Gateway | Modbus RTU | The 460MRSDS moves data between a Modbus RTU Client and a DeviceNet Client. Directly map Modbus RTU Register and Coil data to a DeviceNet Client. |
Modbus RTU Client to EtherNet/IP Adapter Gateway, 460ECMRS | Network Gateway | Modbus RTU | The 460ECMRS moves data between a Modbus RTU Client and an EtherNet/IP Adapter. Directly map Modbus RTU Register and Coil data to an EtherNet/IP Adapter. |
Modbus RTU Client to ASCII Gateway, 460MRSA | Network Gateway | Modbus RTU | The 460MRSA moves data between a Modbus RTU Client and your ASCII device. Directly map ASCII data to a Modbus RTU Client. |
Modbus RTU Client to a Modbus TCP/IP Client Gateway, 460MSMRS | Network Gateway | Modbus, Modbus TCP | The 460MSMRS moves data between a Modbus RTU Client and a Modbus TCP Client. Directly map Modbus RTU Register and Coil data to a Modbus TCP Client. |
Modbus RTU Client to a BACnet/IP Client Gateway, 460MRSBS | Network Gateway | Modbus RTU | The 460MRSBS moves data between a Modbus RTU Client device and a BACnet/IP Building Management System (BMS). |
Modbus RTU Client to BACnet/IP Server, 460 MRSBC | Network Gateway | Modbus RTU | The 460MRSBC moves data between a Modbus RTU Client device and up to 32 BACnet/IP Server devices. The 460MRSBC module bundles your BACnet/IP data and makes it available as Modbus RTU data. The module provides complete Modbus RTU Server and BACnet/IP Client capability. |
Modbus RTU Client to an EtherNet/IP Scanner Gateway, 460ESMRS | Network Gateway | Modbus RTU | The 460ESMRS moves data between a Modbus RTU Client and an EtherNet/IP Scanner. Directly map Modbus RTU Register and Coil data to an EtherNet/IP Scanner |
DeviceNet Server to a Modbus RTU Client Gateway, 460MRSDM | Network Gateway | Modbus RTU | The 460MRSDM moves data between up to 32 DeviceNet Server devices and a Modbus RTU Client. Directly map DeviceNet data to registers and coils in a Modbus RTU Client. |
Modbus RTU Server to EtherNet/IP Scanner Gateway, 460ESMM | Network Gateway | Modbus RTU | The 460ESMM connects up to 32 Modbus RTU server devices to an EtherNet/IP controller. It's the perfect tool to save legacy Modbus RTU devices from the scrap pile and give you the ability to use the huge variety of Modbus RTU devices available in your EtherNet/IP Architectures. |
Modbus RTU Servers to DeviceNet Servers, 460 MMDM | Network Gateway | Modbus RTU | The 460MMDM moves Registers and Coils between up to 32 Modbus RTU Servers and a network of up to 32 DeviceNet Servers. It's the perfect tool to get your Modbus RTU Server data connected to your DeviceNet Server devices. |
Modbus RTU Server to BACnet MS/TP Gateway, 460MMBMS | Network Gateway | Modbus RTU | The 460MMBMS moves data between up to 32 Modbus RTU Server devices and a BACnet MS/TP Building Automation System (BAS). It's a perfect tool to tie Modbus power meters, boilers, chiller and other devices into your BACnet MS/TP Building Automation System. |
Modbus RTU Server to Ethernet TCP/IP Gateway, 460MMTCP | Network Gateway | Modbus RTU | The 460MMTCP moves data between up to 32 Modbus RTU Server devices and an ASCII device. Directly map Modbus RTU Register and Coil data to an Ethernet TCP/IP device. |
Modbus RTU Server to ASCII Device Gateway, 460MMA | Network Gateway | Modbus RTU | The 460MMA moves data between up to 32 Modbus RTU Server devices and an ASCII device. Directly map Modbus RTU Register and Coil data to an ASCII device. |
Modbus RTU Server to Allen-Bradley PLC Gateway, 460ETCMM | Network Gateway | Modbus RTU | The 460ETCMM moves data between up to 32 Modbus RTU Server devices and up to 5 different Allen-Bradley PLCs. Directly map Modbus RTU Server data and user defined Tags or Registers in the data table of your Allen-Bradley PLC. |
Modbus TCP Source Code, 495MTC or 495MTS | Software - Programming | Modbus TCP | Quickly and easily add Modbus TCP communications to your products with the Real Time Automation Modbus TCP Client/Server and development kits. Developed specifically for industrial platforms and fully integrated with any number of RTOS systems and TCP/IP stacks, you can have Modbus TCP communications in days not weeks, months or years. The development kit includes everything you need to implement your Modbus TCP networking solution; "no royalty," single task source code, sample objects, PC Tools, a ready-to-run sample application, complete documentation and much more. |
Modbus RTU Server to DeviceNet Client Gateway, 460MMDS | Network Gateway | Modbus RTU | The 460MMDS moves Registers and Coils between up to 32 Modbus RTU Servers and a DeviceNet Client. It's the perfect tool to get your Modbus RTU Server data connected to your DeviceNet Client. |
Modbus RTU Server to BACnet/IP Client Gateway, 460MMBS | Network Gateway | Modbus RTU | The 460MMBS moves data between up to 32 Modbus RTU Server devices and a BACnet/IP Client. Directly map Modbus RTU register and coil data to BACnet/IP network. |
Modbus RTU Router to ASCII and TCP/IP Device, BFR3000 | Network Gateway | Modbus RTU, Modbus TCP | The easiest way to move Modbus Registers and Coils between Modbus TCP and Modbus RTU Network Devices. The BFR3000 offers transparent data transfer between Modbus devices and controllers on different physical layers. The BFR3000 has three operating modes for moving data between Modbus Networks. |
Exlink PCB Gateway, 6102-EX | Network Gateway | Modbus, Modbus TCP/IP | With a high-speed TTL serial interface (230 Kbps), extremely small footprint and high performance 10/100 Mb network interface, the 6102-EX Ethernet board level gateway is a great option for quickly adding EtherNet/IP and Modbus TCP communications to your standard product line. Based on a very powerful 55-Mhz ARM7TDMI RISC core, the 6102 is a simple, powerful and cost-effective solution for Ethernet networking. |
News items about this company:
MQTT Gateways Create an Easy Way to Move Factory Floor Data to Cloud Application Services
Real Time Automation releases the MQTT protocol on their bestselling 460 industrial gateway line. With an MQTT protocol gateway, it is easier than ever before to move industrial device data to cloud applications like AWS IoT Core, IT or enterprise systems.
Click here for more information...
Copyright © 2005-2024 Modbus Organization, Inc. 800 Federal St., Andover, MA 01810. All rights reserved.
By using Modbus.org, you accept the terms of our visitor agreement and privacy policy.