Modbus TCP to 'C' Programmable Serial, 4 Port, 5202-MNET-ADM4
Type:
Network Gateway
Description:
The Modbus TCP (MNET) driver can be used to interface many different protocols into the Schneider Electric Quantum family of processors as well other software solutions supporting the protocol; Supports both Client and Server connections; The ADM functionality allows the module to be programmed to accommodate devices with unique serial protocols. The module includes General Software Embedded DOS 6-XL, which provides DOS compatibility and real-time multitasking functionality. Developers can use standard DOS tools, such as DigitalMars C++ and Borland compilers.
Connectivity:
Modbus TCP
Features:
Communicates between dissimilar networks; Shared database exchanges information from devices on both networks; View diagnostics between both networks; Modbus TCP adds Ethernet capability to one of the most widely used industrial protocols; Suitable for SCADA and "foreign device" interface applications; Supports floating point data, including configurable support for Enron and Daniel floating point applications; Communicate with programmable controllers, intelligent devices, sensors and instruments; Allows PCs and HMIs to monitor field devices; Develop and deploy 'C' applications for a custom implementation, or protect a proprietary algorithm; Interface Modbus TCP devices to serial devices such as bar code scanners, alarm/status printers, terminal port emulation, and legacy serial protocols; Up to four fully programmable serial ports available; Rapidly create specialized applications with a familiar programming language; Libraries include functions for backplane, ports, configuration, and data communication
Specifications:
24 VDC nominal 18 to 32 VDC; Positive, Negative, GND Terminals 2.5 mm screwdriver blade; Current Load 500 mA max @ 32 VDC max; Operating Temp -4° F to 122° F (-20° C to 50° C); Storage Temp -40° F to 185° F (-40° C to 85° C); LED Indicators; Configuration Serial Port DB-9M RS-232 only; No hardware handshaking; Ethernet Port (Ethernet modules only) 10Base-T half duplex RJ45 ConnectorLink and Activity LED indicators; Electrical Isolation 1500 V RMS at 50 Hz to 60 Hz for 60 s, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration; Application Ports Modbus Plus Connector Two DB9 Female Standard Modbus Plus connectors; Serial Port Isolation 2500 V RMS port signal isolation per UL 1577 3000 VDC min. port to ground and port to logic power isolation
Copyright © 2005-2024 Modbus Organization, Inc. 800 Federal St., Andover, MA 01810. All rights reserved.
By using Modbus.org, you accept the terms of our visitor agreement and privacy policy.