Modbus Organization

Advantages of Joining | Join Form | Toolkit | Subscribe to Newsletter

Text Size: smallmediumlarge
 Back to Company

 

Define Instruments

Zen Datalogger 16 Channel Control & Monitoring Station, ZEN-LOG

Type:  Remote Terminal Unit
Description:  Get your data acquisition (DAQ) requirements fulfilled with the Zen Datalogger. This flexible 16-channel control and monitoring station logs data onto a 1GB Micro SD card, so you can physically take your data with you or route it to other hardware. The 16 isolated universal input channels accept TC, RTD, mA, mV, V, Frequency and Counter inputs, enabling you to reduce the number of separate instruments you need for your application, keeping things simple for maintenance and troubleshooting. Modbus RTU and Modbus TCP are provided for simple integration with SCADAs and PLCs. Learn more about this Data Logging Control and Monitoring Station.
Connectivity:  Modbus RTU, Modbus TCP
Features:  16 Isolated universal inputs; Data logging up to 1GB with removable SD card; Modbus integration with SCADAs and PLCs; 2 Relay outputs; 2 Analog outputs; 4 Digital inputs; HMI connection; RS422, RS232/RS485 (Modbus RTU), Ethernet (Modbus TCP); Easy USB programming and data log retrieval using Define WorkBench
Specifications:  16 Isolated universal input channels; Current, Voltage, RTD, Thermocouple, Potentiometer, Digital Pulse, Current Sensor or Attenuator input; Simple unit configuration via USB; Real-time clock; Data logging to 1GB Micro SD card; On-board memory capacity 32MB (used when Micro SD card is removed); Fast, simple data log retrieval and visualisation using Define WorkBench; 2 x relay outputs (5A 30V DC); 2 x Isolated 4-20mA analog outputs; Comm port 1 select Ethernet Modbus TCP (10/100/Auto) or RS422 / RS485; Comm port 2 RS232 / RS485 Modbus RTU; 4 x Opto isolated digital inputs; Intelligent multiplexer mode available; Expansion interface for ZEN-RIO; HMI interface for remote display; Power supply HV (85-265V AC / 95-370V DC) or MV (24-48V AC / 17-72V DC); Supply frequency 50/60Hz, 10VA; Mains isolation 250V AC; Thermocouple input B E J K N R S or T type; RTD PT100 or PT1000; RTD range -200 to 300°C (-328 to 572°F) 0.01°C resolution OR -200 to 800°C (-328 to 1472°F), 0.1°C resolution; Current input 0-20mA, 4-20mA; Voltage input ±200mV, -200mV to 1V, 0-10V, 0-18V; Digital pulse input 0-2500.0Hz (0-50Hz debounced); Open collector (NPN, PNP), TTL or Clean Contact; 3-wire Potentiometer input <2kΩ low pot, >2kΩ high pot; AC Current sensor input; Attenuator input; Input isolation 2,500V AC for 1 minute between all input channels; Resolution 16 bits; Accurate to <±0.1% FSO; Dimensions (H x W x D): 59 x 255 x 144mm (2.32 x 10.04 x 5.67")