Zen RTU Remote Terminal Unit, ZEN-RTU
Type:
Remote Terminal Unit
Description:
Get 16 signals into your PLC or SCADA system! If you need to collate multiple signal input types and route them to your PLC or SCADA system, choose the Zen RTU. This flexible and powerful monitoring and control station has four digital inputs and an RS485 Modbus/RTU port. Additionally, it has an Ethernet port that can be selected as Modbus TCP, or EtherNet/IP (ODVA CONFORMANT) for connection to Logix Controllers, FactoryTalk View etc. The Zen RTU is available with 16 Isolated Universal Inputs and accepts Current, Voltage, RTD, TC, Frequency, Counter and more. An RTD-only, Non-isolated version can also be selected as a cost-effective option for multi-channel temperature applications where isolation is not required.
Connectivity:
Modbus RTU, Modbus TCP
Features:
16 Isolated universal inputs OR 16 Non-isolated RTD inputs; Modbus integration with SCADAs and PLCs; ODVA CONFORMANT EtherNet/IP option; 4 Digital inputs; RS232/RS485 (Modbus RTU), Ethernet (Modbus TCP); Easy USB programming using Define WorkBench
Specifications:
16 Isolated universal input channels OR 16 Non-isolated RTD input channels; Universal inputs: Current, Voltage, RTD, Thermocouple, Potentiometer, Digital Pulse, Current Sensor or Attenuator input; Simple unit configuration via USB; Fast, simple programming using Define WorkBench; Comm port 1 select Ethernet Modbus TCP (10/100/Auto) or EtherNet/IP; Comm port 2 RS232 / RS485 Modbus RTU; 4 x Opto isolated digital inputs; Power supply HV (85-265V AC / 95-370V DC) or MV (24-48V AC / 17-72V DC); Supply frequency 50/60Hz, 10VA; Mains isolation 250V AC; Thermocouple input B E J K N R S or T type; RTD PT100 or PT1000; RTD range -200 to 300°C (-328 to 572°F) 0.01°C resolution OR -200 to 800°C (-328 to 1472°F), 0.1°C resolution; Current input 0-20mA, 4-20mA; Voltage input ±200mV, -200mV to 1V, 0-10V, 0-18V; Digital pulse input 0-2500.0Hz (0-50Hz debounced); Open collector (NPN, PNP), TTL or Clean Contact; 3-wire Potentiometer input <2k Ω low pot, >2k Ω high pot; AC Current sensor input; Attenuator input; Input isolation 2,500V AC for 1 minute between all input channels (Universal inputs only); Resolution 16 bits; Accurate to <±0.1% FSO; Dimensions (H x W x D): 59 x 255 x 144mm (2.32 x 10.04 x 5.67")
Copyright © 2005-2024 Modbus Organization, Inc. 800 Federal St., Andover, MA 01810. All rights reserved.
By using Modbus.org, you accept the terms of our visitor agreement and privacy policy.